Directions for use
A. Filter Element/Prefilter
I. Preparation:
1.
Prepare BallastGuard CIP Cleaner at 1:20 ratio (
1L: 20L Demin/Distilled/RO grade water/potable water)
2.
The pH value will be app. pH 2 ~ 3
3.
Use pH paper or pH pen to measure on the solution
prepared
4.
Pre-rinse the filter to remove any contaminant
(dirt, mud, sand, shells, etc) prior using the cleaning solution for more
effective cleaning.
5.
Clean the screen/filter with pressure washer
from the outside surface.
II. Acid Cleaning:
1.
Cleaning be done by spread, dip or spray for 1 ~
4 hours depending on the degree of scaling appearance.
2.
Rinse off/spray with running hot water (at least
60°c) until complete neutralization (pH=6.5-
7.5). Check the wash water pH.
3.
Blowdry the filter element/pre-filter with
instrument air/compressed air.
4.
Inspect the filter element externally for
cleanliness.
5.
If needed, repeat the cleaning step but reduce
the cleaning spread, dip or spray to 30 mins
6.
Note: Recommend to follow cleaning instruction
from equipment OEM if available.
B. CIP Cleaning:
I. Preparation:
1.
Prepare BallastGuard CIP Cleaner at 1:20 ratio (
1L: 20L Demin/Distilled/RO grade water/potable water)
2.
The pH value will be app. pH 2 ~ 3
3.
Use pH paper or pH pen to measure on the solution
prepared
II. CIP Cleaning:
1.
Fill the CIP cleaning tank with the prepared
cleaning solution
2.
Follow CIP Cleaning instruction based on CIP
Equipment package
Note: Follow cleaning instruction from equipment
OEM if available